Portable Digital Coating Thickness Gauge TIME®2600 adopts two thickness-measuring methods: magnetic induction (ferrous) and eddy current (non-ferrous). It can rapidly, nondestructively, and precisely measure the thickness of non-magnetic coating on magnetic metal substrate, and the thickness of non-conductive coating on non-magnetic metal substrate. This paint meter can be euipped with 6 optional probes for different applications. It is suitable for both field testing and laboratory research.
Portable Digital Coating Thickness Gauge TIME®2600 adopts two thickness-measuring methods: magnetic induction (ferrous) and eddy current (non-ferrous). It can rapidly, nondestructively, and precisely measure the thickness of non-magnetic coating on magnetic metal substrate, and the thickness of non-conductive coating on non-magnetic metal substrate. This paint meter can be euipped with 6 optional probes for different applications. It is suitable for both field testing and laboratory research.
Features
Technical Specification
|
Probe types |
F |
N |
|
|
Measuring methods |
magnetic induction |
eddy current |
|
|
Measuring range |
0 ~1250 μm |
0 ~1250 μm, 0 to 40μm (for chrome plate on copper) |
|
|
Minimum resolution |
0.1μm |
||
|
Tolerance |
Zero point calibration |
±(3%H+1)μm |
± (3%H+1.5)μm |
|
H means the thickness of tested piece |
|||
|
Two points calibration |
±[(1~3)%H+1]μm |
±[(1~3)%H+1.5]μm |
|
|
H means the thickness of tested piece |
|||
|
Measuring condition |
Min. curvature radius (mm) |
Convexity 1.5 |
Convexity 3 |
|
Min. testing area diameter (mm) |
Ø7 |
Ø5 |
|
|
Critical thickness of substrate(mm) |
0.5 |
0.3 |
|
| Standards | DIN,ISO,ASTM,BS | ||
| Calibration | Zero and foil calibration | ||
| Interface | RS232 | ||
| Statistic | Number of measurement, mean, standarddeviation, maximum and minimum | ||
| Data memory | 640 readings | ||
| Limits | Adjustable with alarm | ||
| Power | NiMH rechargeable battery | ||
|
Operating environment |
Temperature: 0~40? | ||
| Humidity: 20%~90% | |||
| No strong magnetic field | |||
| Dimensions (mm) | 230×86×47 | ||
Optional Probes and Application Guide
|
Probe model |
F400 |
F1 |
F1/90º |
F10 |
N1 |
CN02 |
|
|
Operating principle |
Magnetic induction |
Eddy current |
|||||
|
Measuring range (µm) |
0-400 |
0-1250 |
0-10000 |
0 to 1250 μm |
10~200 |
||
|
Low range resolution (µm) |
0.1 |
0.1 |
10 |
0.1 |
1 |
||
|
Accuracy |
One-point calibration (µm) |
±(3%H+1) |
±(3%H+10) |
±(3%H+1.5) |
±(3%H+1) |
||
|
Two-point calibration (µm) |
±[(1~3)H%+0.7] |
±[(1~3)H%+1] |
±[(1~3)%H+10] |
±[(1~3)%H+1.5] |
– |
||
|
Measuring conditions |
Min curvature of the min area (mm) |
Convex 1 |
1.5 |
Flatten |
10 |
3 |
Flatten |
|
Diameter of the min area (mm) |
φ3 |
φ7 |
φ7 |
φ40 |
φ5 |
φ7 |
|
|
Critical thickness of substrate (mm) |
0.2 |
0.5 |
0.5 |
2 |
0.3 |
unlimited |
|

Butuh Bantuan? Hubungi Kami