| Supply voltage |
100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC |
| Allowable power supply voltage range |
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC |
| Power consumption (See note 1.) |
100 to 240 VAC: 18 VA max. (max. load)
24 VAC/DC: 11 VA/7 W max. (max. load) |
| Current consumption |
DeviceNet power supply: 50 mA max. (24 VDC) |
| Input |
No-voltage contact, voltage pulse, open collector |
| External power supply |
12 VDC 10%, 80 mA (for models with external power supplies only) |
| Event inputs (See note 2.) |
Hold input |
NPN open collector or no-voltage contact signal
ON residual voltage: 2 V max.
ON current at 0 Ω: 4 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 0.1 mA max. |
| Reset input |
| Bank input |
| Output ratings (depends on the model) |
Relay output |
250 VAC, 30 VDC, 5 A (resistive load)
Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations |
| Transistor output |
Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 μA max. |
| Linear output |
Linear output 0 to 20 mA DC, 4 to 20 mA:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS
(1 V or less: ±0.15 V; not output for 0 V or less) |
| Display method |
Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green)) |
| Main functions |
Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset |
| Ambient operating temperature |
-10 to 55°C (with no icing or condensation) |
| Ambient operating humidity |
25% to 85% |
| Storage temperature |
-25 to 65°C (with no icing or condensation) |
| Altitude |
2,000 m max. |
| Accessories |
Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) |