● Precise and stable horizontal and vertical linearity with horizontal linearity 0.1% and vertical linearity 2%
● High performance square wave pulser with tuning option.
● DAC,AVG,DGS curves and defect echo help to evaluate defect equivalent calculation
●Two high resolution scanning mode: A and B
● Four ways to present waveform: positive half-wave, negative half- wave, full wave and radio frequency.
● Automatic gain adjustment, defect equivalent calculation and peak memory function
● Display of echo envelope
● Two individual gates setting and alarming function.
● Gate measurement includes echo amplitude, beam path, depth, projection and so on.
● Waveform freeze available:in full ,peak, comparative and envelope ways
● 50 detecting channels are available with separate detecting parameters and DAC (Distance Amplitude Correction) curves in every channel.
● Three detecting modes(single-probe, dual crystal probe and transmission) with automatic calibration function
● Connected to PC via USB interface with advanced software for data analysis and management.
● Super large memory, 1000 waveform diagrams can be stored.
● EPSON ink-jet printers can be connected with TUD 500
●Real-time waveform display and review
Specification
| Items | Description | 
| Scanning range | 2.5 mm ~9999 mm | 
| Scanning | 0.1mm (2.5mm ~100mm) | 
| resolution | 1mm (100 mm ~5000mm) | 
| Gain range | 0dB ~110 dB | 
| D-delay | -20µs~+3400µs | 
| P-delay | 0.000~750.000 | 
| Sound speed | 600 m/s~16000m/s | 
| Bandwidth | 0.1MHz~15MHz | 
| Vertical linearity accuracy | ≤2% | 
| Horizontal linearity accuracy | ≤0.1% | 
| Dynamic range | 100dB | 
| Rectification | Positive half wave, negative wave, full wave, and RF | 
| Sensitivity leavings | ≥62dB | 
| Test mode | Pulse-echo, dual and through transmission | 
| Pulser | Square pulse | 
| Damping | 50ohms, 100ohms ,200ohms,500 ohms | 
| Reject | Linear, 0-80% of full screen | 
| Unit | Metric/inch | 
| Interface | RS232 / USB | 
| Printer | EPSON ink-jet printers | 
| AC requirements | Input: 100-240~50/60Hz | 
| Temperature | -10℃~40℃ | 
| Humidity | 20%~90%RH | 
| Power | 2×3.7V 5000mAh | 
| Charging time | 8h | 
| Dimension (mm) | 300×180×57 | 
| Weight (g) | 2000 | 
| Standard Delivery | Optional Accessory | |
| Main unit | 1 | RS232 communication cable | 
| Li battery | 2sets | USB communication cable | 
| Power adapter (3A/9V) | 1 | Flash disk | 
| LEMO-Q9 probe connecting cable | 1 | Printer | 
| LEMO-Q6 Probe connecting cable | 1 | |
| Neck strap | 1 | |
| Wrist strap | 1 | |
| Hood | 1 | |
| Straight beam probe | 1 | |
| Angle beam probe | 1 | |
| Couplant | 1 | |
| TIME certificate | 1 | |
| Warranty card | 1 | |
| Instruction manual | 1 | 
Applications
- Roller Flaw Detection

- Welding Flaw Detection
 
 
 
				 
															 
								 
								 
								