B6F stainless steel single point load cell, OIML approved (150kg-2t)
Features
- Stainless steel IP67 single point load cell.
- Bending beam.
- Suitable for mobile weighing systems, garbage trucks, belt scales, container and tank scales, etc.
- High accuracy
- Recommended maximum platform size
- for 150kg: 400 x 400 mm
- for 250kg – 500kg: 600 x 800 mm
- for 750kg – 2t: 1200 x 1200 mm
| Capacity |
Accuracy |
|
| 150 kg |
C3 (Excluded from OIML) |
B6F-C3-150kg-3B6 |
| 250 kg |
C3 (Excluded from OIML) |
B6F-C3-250kg-3B6 |
| 500 kg |
C3 |
B6F-C3-500kg-3B6 |
| 750 kg |
C3 |
B6F-C3-750kg-3B6 |
| 1000 kg |
C3 |
B6F-C3-1000kg-3B6 |
| 2000 kg |
C3 |
B6F-C3-2000kg-3B6 |
| Parameter |
Value |
| Accuracy Class |
C3 OIML R60 |
| Output Sensitivity |
2.0 ± 0.2 mV/V |
| Maximum Capacity |
150, 250, 500, 750, 1000, 2000 kg |
| Max. LC Intervals (nLC) |
3000 |
| Min. Verification Interval Ratio (Y) |
10000 / 12000 |
| Combined Error |
≤ ±0.023 %FS |
| Creep Error (30 min) |
≤ ±0.0245 %FS |
| Temp. Effect on Zero (ZTC) |
≤ ±0.014 %FS/10°C |
| Temp. Effect on Sensitivity (STC) |
≤ ±0.011 %FS/10°C |
| Zero Balance |
≤ ±1.5 %FS |
| Safe Overload |
150 %FS |
| Ultimate Overload |
300 %FS |
| Eccentric Loading Error |
±0.002 %Ld/cm |
| Excitation Voltage (Recommended) |
5 ~ 12 V |
| Excitation Voltage (Max) |
18 V |
| Input Resistance |
384 ± 4 Ω |
| Output Resistance |
350 ± 3 Ω |
| Insulation Resistance |
≥ 5000 MΩ |
| Compensated Temperature |
-10 ~ +40 °C |
| Operating Temperature |
-35 ~ +65 °C |
| Material |
Stainless Steel |
| Ingress Protection |
IP67 |
| Fixation Bolt Torque |
M12: 100 Nm, M16: 160 Nm |
| ATEX (Optional) |
II 1G Ex ia IIC T4 Ga, dll |