Capacity Accuracy Full Article Description
| Parameter | Value |
|---|---|
| Accuracy Class | OIML R60 C3 |
| Output Sensitivity | 2.0 ± 0.2 mV/V |
| Maximum Capacity (Emax) | 6, 12, 30, 60 kg |
| Max. Number of LC Intervals (nLC) | 3000 |
| Ratio of Min. Verification Interval (Y) | 10000 |
| Combined Error | ≤ ±0.023 %FS |
| Creep Error (30 minutes) | ≤ ±0.016 %FS |
| Temperature Effect on Zero (ZTC) | ≤ ±0.015 %FS/10°C |
| Temperature Effect on Sensitivity (STC) | ≤ ±0.011 %FS/10°C |
| Zero Balance | ≤ ±1.5 %FS |
| Safe Overload | 150 %FS |
| Ultimate Overload | 300 %FS |
| Maximum Deflection | 6–12 kg: ~0.17 mm; 30 kg: 0.13 mm; 60 kg: 0.12 mm |
| Eccentric Loading Error | ±0.002 %Ld/cm |
| Excitation Voltage (Recommended) | 5 ~ 12 V |
| Excitation Voltage (Maximum) | 18 V |
| Input Resistance | 400 ± 20 Ω |
| Output Resistance | 351 ± 2 Ω |
| Insulation Resistance (50V) | ≥ 5000 MΩ |
| Compensated Temperature | -10 ~ +40 °C |
| Operating Temperature | -35 ~ +65 °C |
| Storage Temperature | -40 ~ +70 °C |
| Load Cell Weight | ~ 1.2 kg |
| Element Material | Stainless Steel |
| Ingress Protection | IP68 |
| Fixation Bolt Torque | M6: 10 Nm |
| ATEX Classification (Optional) | II 1G Ex ia IIC T4 Ga; II 1D Ex ia IIIC T 200 135°C Da; II 3G Ex ic IIC T4 Gc |