FITUR
* Pemantauan online & real-time
* Kaca film sensitif impedansi rendah
* RS485 dan output 4-20mA pada saat yang sama, terhubung langsung ke komputer dan sistem PLC
* Pengulangan yang baik dan stabilitas termal
* Isolasi sinyal internal, anti gangguan kuat
* Catu daya secara luas
* Standar Tahan Air IP68
* Drift rendah, ukuran kecil, respon cepat
* Instalasi mudah, sederhana
* Kinerja stabil dan umur panjang
* Konektor penerbangan adalah opsional untuk memfasilitasi penggantian elektroda
APLIKASI
* Perlindungan lingkungan
* Pertanian
* Akuakultur
* Pemeliharaan air
* Pengolahan limbah
* Remediasi tanah
TECHNICAL SPECIFICATION
|
Item
|
Technical Specification
|
| Measurement Principle |
Electrochemistry |
| Range |
0-14PH
|
| Supply |
7-30VDC(power consumption<0.2W) |
| Accuracy |
±0.05PH
|
| Resolution |
0.01PH
|
| Response time |
<10s (soil moisture>30%)
|
| Stability |
≤0.01PH/24h
|
| Output Signal |
4-20mA & RS485 at the same time
|
| Calibration Cycle |
Every 6 month
|
| Operating Environment |
0-+80℃(<0.6MPa)
|
| Cable length |
5m(default),customizable |
| Probe material |
304SS |
| Ingress Protection |
IP68 |
| Storage |
10-60℃@20%-90%RH |
PH SCALE
| PH value |
Description |
PH value |
Description |
| <4.5 |
Strongly acidity |
7.5-8.5 |
Faintly alkalinity |
| 4.5-5.5 |
Acidity |
8.5-9.5 |
Alkalinity |
| 5.5-6.5 |
Faintly acidity |
>9.5 |
Strongly alkalinity |
| 6.5-7.5 |
Neutral |
|
|
ELECTRODE MAINTENANCE
PH electrode is not used at ordinary times and can be soaked in 3mol/l KCL solution or saturated KCL solution. It is strictly prohibited to immerse the electrode in distilled water and deionize the water or tap water with minimal plasma content.If the PH electrode is contaminated with inorganic substances, it can be cleaned with 0.1mol/l Hcl or NaOH solution for a few minutes and then washed with distilled water. If the PH electrode is contaminated with organic substances, it can be cleaned with alcohol or acetone and then cleaned with distilled water.(note: the protective cap before the electrode should be removed when using);
Clean the electrode with tap water every 3 months or 6 months according to the working environment.
PARAMETER SELECTION TABLE
|
Remark
|
Series
|
Type
|
Supply
|
Output
|
Cable Length
|
|
|
RK
|
|
|
|
|
|
|
|
|
500
|
|
|
|
|
|
|
|
|
22 |
|
|
|
|
|
|
|
A |
|
|
7-30V |
|
|
|
X |
|
|
Other |
|
|
|
|
A |
|
4-20mA |
|
|
|
|
|
B
|
|
RS485
|
|
|
|
|
|
X
|
|
Other
|
|
|
|
|
|
|
5000 |
Unit(mm)
|
|
|
|
|
|
|
…
|
Unit(mm)
|
Example: RK500-22AA5000 Supply:7-30V, Output:4-20mA,Cable length:5m.